Promag CON-485 Series Informations techniques Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
Proline Promag 50W, 53W
8 Endress+Hauser
Electrical connection remote
version
F06-5xFxxxxx-04-xx-xx-en-001
n.c. = isolated cable shields, not connected
Cable entry Power-supply and signal cables (inputs/outputs):
Cable entry M20 x 1.5 (8…12 mm)
Sensor cable entry for armoured cables M20 x 1.5 (9.5...16 mm)
Threads for cable entries 1/2" NPT, G 1/2"
Connecting cable for remote version:
Cable entry M20 x 1.5 (8…12 mm)
Sensor cable entry for armoured cables M20 x 1.5 (9.5...16 mm)
Threads for cable entries 1/2" NPT, G 1/2"
53***-***********M Status input Frequency output Frequency output
Current output
HART
53***-***********N Current output Frequency output Status input MODBUS RS485
53***-***********P Current output Frequency output Status input PROFIBUS DP
53***-***********V Relay output 2 Relay output 1 Status input PROFIBUS DP
53***-***********2 Relay output Current output Frequency output
Current output
HART
53***-***********4 Current input Relay output Frequency output
Current output
HART
53***-***********7 Relay output 2 Relay output 1 Status input MODBUS RS485
Ground connection, power supply Page 6
Terminal No. (inputs / outputs)
Order variant 20 (+) / 21 (–) 22 (+) / 23 (–) 24 (+) / 25 (–) 26 (+) / 27 (–)
6
5
5
7
7
8
4
4
37
37
36
42
42
41
41
E1 E2
GND
E
2
1
brown
white
green
yellow
n.c. n.c.n.c.
S1
E1 E2
S2 GND
E
S
EPD
Coil circuit
Pipe
Electrode circuit
Meas. signal
Vue de la page 7